  • Output must be directly connected to the load.
  • Output must not be used to control receptacles.
  • Listed in accordance to CAN / ULC S142 standard method of fire test for heat and visible smoke release for discrete products.
  • Complies with the limits for a Class B device, pursuant to IC and FCC rulesĬomplies with requirements for use in other spaces used for environmental air (plenums) per NEC® 2014 300.22(C)(3).
  • Installation guide: RMJSPNEDV_InstallationInstructions ġ See App Note #628 (P/N 048628) on for emergency lighting applications.
  • Mounts in a standard metal 4 in x 4 in (101.6 mm x 101.6 mm) junction box.įor more information, see the following documents:.
  • Receives wireless inputs from up to 10 Pico remote controls, 10 Radio Powr Savr occupancy / vacancy sensors, and 1 Radio Powr Savr daylight sensor Utilizes Lutron Clear Connect – Type A RF Technology (see frequency range on page 2).
  • NEMA SSL 7A-2015 compliant for compatibility with solid state lighting.
  • 10-year power failure memory automatically returns the outputs to the levels they were set to prior to a power outage.
  • Buttons on the PowPak module provide override control.
  • See App Note #781 (P/N 048781) on for more information.
  • LEDs on the PowPak module provide diagnostic information.
  • Integral protection for common temporary over-current and over-voltage conditions.
  • RTISS-ICM technology is able to withstand high inrush LEDs, bulb blowouts, and direct shorts.
  • Can be mounted horizontally or vertically.

    lutron power booster

    RTISS technology compensates for incoming line variations such as frequency shifts (up to +/- 2%change in frequency / second), harmonics and line noise.Model (RMJS-PNE-DV-EM) available for use with emergency lighting.Can be changed to forward-phase mode using button presses or the Vive app. Phase selectable (non-automatic): Operates in reverse-phase mode by default.

    #Lutron power booster pro#

    PRO LED+ is Lutron’s industry-leading technology which enables either forward or reverse-phase control for optimal dimming down to as low as 1% (dependent on the driver’s capabilities).Neon/cold cathode light (with step-up phase control transformers).

    #Lutron power booster drivers#

    LED fixtures with phase control drivers.120 / 277 V~ voltage phase control for various phase dimmable fixture types (see page 4):.Model Number Region Operating Voltage Frequency Band RMJS-PNE-DV U.S.A., Canada, Mexico 120 / 277 V~ 431.0 –437.0 MHz RMJS-PNE-DV-EM U.S.A., Canada, Mexico 120 / 277 V~ 431.0 –437.0 MHz Features